Latest from New Products

Infinitum Electric
hpac0225_infinitumgen4heavydutyprimary
Rob McManamy
20250210_133435
Greenheck
hpac0125_greenheck_ervi10primary
Smith & Loveless
screenshot_20241217_162401
Johnson Controls
newsjohnsoncontrolsyorkykcp
WaterFurnace International
hpac0824_waterfurnace_truclimate_900primary
Navien Product Announcements Graphic 700x380 65170d7c20617

Navien Announces First HVAC Product via Virtual Launch

Sept. 29, 2023
New NPF Hydro-furnace marks manufacturer's first entry into HVAC market. New water heaters, condensing boilers also unveiled.

PRESS RELEASE

Irvine, CA (September 26, 2023) – Navien, Inc., the number one brand in high efficiency condensing tankless water heaters, combi-boilers, and wall-hung boilers in North America, announced three new innovations, including its first HVAC product, during a virtual launch event on September 26.

Central to the launch event was Navien’s announcement of the NPF Hydro-furnace, their introduction into the HVAC market. Available in Upflow and Horizontal configurations, the NPF comes in two sizes of 60,000 BTU/h and 100,000 BTU/h that both boast 97.0% AFUE and meet the stringent requirements of SCAQMD rule 1111 for Ultra-Low NOx performance.

The NPF uses Navien’s industry-proven dual stainless steel heat exchangers to heat water in an isolated compartment out of the airstream which provides sound-reduction and energy efficiency. The heated water is circulated through a hydronic coil which transfers the heat into the airstream for the ultimate in quiet forced-air heating comfort. The sealed combustion design allows the NPF to deliver comfortable heat without significantly impacting humidity levels at one of the quietest sound levels of any furnace on the market. The NPF features industry leading variable capacity that can modulate down to 15% for an unparalleled level of comfort that allows the unit to meet year-round heating needs.

An EZNav unit-mounted interface with built-in setup wizard provides easy, intuitive steps for startup, configuration, and diagnostics. Installers can set supply air temperature and airflow directly from the front panel, and the service wizard will walk contractors through component verification to aid in troubleshooting. Each NPF unit is compatible with most one- and two-staged thermostats and can be matched with any AC or heat pump system providing their own dedicated airflow selections and ramping profiles.

A new addition to Navien’s tankless water heater portfolio, the company announced the NHW-A non-condensing tankless water heater, which features the patented ComfortFlow® recirculation pump and buffer tank originally introduced in the NPE-A condensing tankless water heater in 2012. ComfortFlow helps eliminate the “cold water sandwich” effect and resolves the issue of low flow rates found in other tankless water heaters.

ComfortFlow also reduces the wait time for hot water by allowing internal or external recirculation without the need for external parts or controls. Users can program recirculation timing for either always-on, a set weekly schedule using the remote controller, or use the intelligent setting that learns the user’s hot water patterns and automatically adjusts the recirculation schedule to match. Like the NPN, Navien’s first non-condensing product, the NHW-A utilizes the proprietary NaviTech® stainless steel heat exchanger and burner for extreme durability and low NOx emissions.

The NHB-H condensing boiler was announced as an update to the widely popular NHB. The NHB-H keeps much of the high-quality features of the NHB such as industry leading turndown ratios up to 15 to 1, high-efficiency of 95.0% AFUE, field convertibility from natural gas to liquid propane, four sizing options of 55,000 BTU/h, 80,000 BTU/h, 110,000 BTU/h and 150,000 BTU/h, and the ability to common vent and cascade the NHB-110H and NHB-150H models.

New advancements to the NHB-H include the addition of the Vent Installation Detector (VID) for enhanced safety; an advanced front panel controller with an intuitive multi-line LCD display and command dial for quick setup and easy access to data, diagnostics and troubleshooting; built-in controls to run a boiler pump, 3 zone pumps or 3 zone valves; and the availability of a new stainless steel primary manifold kit, which simplifies near boiler piping, reducing installation time and materials.

In addition to product launches, Navien reported on improvements to their NavienRewards contractor rewards program and updates to the Navien products and services app. NavienRewards now offers an updated user interface with more ways to earn and redeem points for the program. The products and services app now features service videos for registered installers and servicers, and push notifications can be enabled by all users for alerts on new products, promotions and more.

Navien will start shipping the NHW-A the first week of October 2023, NHB-H early in January 2024, the NPF Upflow the first week of November 2023, and the NPF Horizontal in January 2024.

About Navien, Inc.

Since 2006, Navien, Inc. has become one of the fastest growing companies in the home comfort sector in North America and has established itself as the leader in condensing technology, providing condensing tankless water heaters, combi-boilers, and wall-hung boilers. In 2018, Navien moved beyond the condensing market with the introduction of the NPN series non-condensing tankless water heater, and now is breaking into the HVAC market. To learn more about Navien, Inc., visit www.navieninc.com.

Contact: Brett Butler, Marketing Communications Manager, [email protected].