Dual-Fuel Systems Offer Path to Decarbonization
By Zachary Golden, Product Manager, Channel Development, Weil-McLain
Hydronic heating has a long history of innovation in the boiler industry, driven by advancements in efficiency, performance and sustainability. The portfolio of many companies’ modern heating solutions includes industry-leading condensing boilers and cast-iron boilers, which have set benchmarks for energy efficiency and reliability.
However, as the market rapidly evolves toward more sustainable practices, there is an increasing focus on technologies such as air-to-water heat pumps and dual-fuel systems to meet growing demand for decarbonization.
The Importance of Hybrid and Dual-Fuel Systems
Decarbonization is a major trend in our industry, driven by global climate initiatives and policy changes. Many manufacturers are taking a hybrid approach by combining the strengths of boilers with air-to-water heat pump technology. This dual-fuel solution provides homeowners with the best of both worlds: the reliable, high-output heating of a boiler for the coldest days of the year, paired with the efficiency of a heat pump for milder conditions.
Dual-fuel systems integrate an air-to-water heat pump with a traditional hot water boiler, where the heat pump manages a significant portion of the seasonal heating load, and the boiler supplements heating only during extreme cold. This approach balances efficiency, performance and comfort while ensuring redundancy and reliability. Most hybrid systems transition to boiler backup around 30°F (+/- 10°F) to ensure optimal efficiency and comfort.
The Role of Water Temperature
One critical difference between heat pumps and boilers lies in water temperature. Heat pumps typically deliver water at around 140°F, whereas many traditional boiler systems operate at 180°F to ensure comfort on the coldest days. However, data show most homes experience peak heating demand for only a short period each year. This trend presents an opportunity to leverage the energy efficiency of heat pumps during milder conditions while relying on high-temperature boiler output only when necessary.
Legislative and Regulatory Drivers
Recent legislative efforts, such as the Inflation Reduction Act, provide incentives for homeowners to adopt energy-efficient technologies. Programs like the Home Efficiency Rebate and Home Electrification Appliance Rebates are designed to subsidize the adoption of heat pumps and necessary electrical infrastructure upgrades. For older homes with legacy cast-iron boilers, this presents a pathway to improve efficiency and decarbonize heating systems.
The dual-fuel approach aligns with these initiatives, providing a transition solution that allows homeowners to integrate modern heating technologies while maintaining system reliability.
Investing in Innovation: The Role of Dual-Fuel Solutions in Modern Heating
The industry continues to invest in the next generation of hydronic heating solutions, with modern dual-fuel systems offering:
- Optimized Efficiency: The heat pump handles much of the heating season, offsetting 70%-80% of the expected heating load, which reduces boiler runtime and lowers energy costs;
 - Advanced Smart Control Systems: Indoor split units manage heat pump operation, ensuring seamless transitions between heat sources.
 - Adaptability for High-Temperature Applications: Heat pumps operate effectively at outdoor temperatures as low as -13°F, with peak supply temperatures reaching 149°F and a Coefficient of Performance (COP) ranging from 4.50 to 5.37 to maintain optimal efficiency;
 - Eco-Friendly Refrigerant: Many modern heat pumps utilize R-32 refrigerant, which offers enhanced efficiency and environmental benefits;
 - Extended Equipment Life Expectancy: By using the heat pump for most of the heating season, boiler wear and tear is reduced, leading to longer system longevity;
 - Staged Installation Flexibility: Homeowners can install components in phases to minimize upfront costs and disruption;
 - Rebate and Incentive Eligibility: These systems qualify for federal, state and local tax credits and rebate programs where available.
 
Smart System Design: Performance Calculators for Optimized Efficiency
To ensure efficiency and ease of integration, advanced performance calculators have been developed to support system design. These tools:
- Conduct load calculations (Manual J) for precise system sizing;
 - Analyze efficiency projections using bin data to maximize heat pump contribution;
 - Enable data-driven decision-making to prioritize comfort and cost savings;
 - Ensure proper application sizing by factoring in heat load, heat pump capacity, heat emitter capacity, domestic hot water (DHW) needs, weather bin data, localized utility rates and rebates.
 
Flexible Installation and Retrofit Options
Dual-fuel systems offer multiple installation pathways to accommodate different customer needs:
- All-at-Once Installation: Suitable for homeowners looking to replace their heating system immediately, with labor efficiencies and lower total installation costs.
 - Phased Installation: If a boiler fails in the winter, a heat pump-ready boiler and indoor unit can be installed first, with the outdoor heat pump added later in warmer months. This reduces upfront costs and allows for future system expansion.
 - Retrofit Upgrade: Homeowners with a heat pump-ready boiler can seamlessly integrate a heat pump into their system with minimal piping changes.
 
Educating Contractors and the Industry
To support the adoption of these technologies, industry leaders provide education and training for contractors. These programs offer training on the latest advancements in heat pump and hybrid system technologies and help contractors understand system design, installation best practices and how to leverage available rebates for their customers. They also provide real-time technical support for troubleshooting and system optimization.
Maximizing Efficiency and Comfort with Adaptive Heating Balance Technologies
Adaptive heating balance technologies enable dual-fuel systems to dynamically adjust heating sources based on real-time conditions. This ensures:
- Steady & Efficient Operation: Longer heat pump runtimes at lower modulation improve efficiency and reduce cycling.
 - Enhanced Comfort: Avoids short, high-intensity cycles for stable indoor temperatures.
 - Seamless Backup Heat: The boiler engages only when needed, such as during extreme weather or defrost cycles.
 - Dynamic Adaptation: The system continuously optimizes its performance based on environmental conditions using temperature-over-time algorithms that adjust heating output in real time.
 
Looking Ahead: The Future of Hybrid Heating
As the HVAC industry continues to evolve, heat pumps are emerging as the foundation for future decarbonization efforts. By integrating heat pumps with boilers and exploring additional technologies like thermal storage and hydronic cooling, the industry can deliver greater energy efficiency and carbon reductions. Manufacturers’ adaptive heating balance technologies ensure seamless transitions between heating sources, maintaining optimal comfort levels year-round.
The industry is committed to merging the legacy of hydronic heating excellence with cutting-edge hybrid technologies, helping homeowners and businesses transition toward more sustainable, efficient heating and electrification-ready solutions.
#####
Based in Michigan City IN, the author is a hydronic leader at Weil-McLain, where he focuses on product-driven designs and innovation in energy-efficient heating technologies, including air-to-water heat pumps, hybrid solutions and decarbonization initiatives.


