NEW PRODUCTS

Renewable-energy-alternatives module

Part of Right-Suite Universal, the Right-SolarDHW module calculates the performance- and operating-cost savings of solar domestic-hot-water-heating systems. By integrating solar options with additional water-heating equipment as a backup fuel source, contractors can produce operating-cost comparisons immediately, including any state or federal tax benefits and incentives. The module uses F-Chart calculations, which widely are accepted as a benchmark design method for solar systems, and high-speed computations to factor the orientation of collector types, such as slope and azimuth, so contractors can consider “what-if” scenarios in collector placement. Using a renewable-energy resource, such as solar energy, provides owners with an environmentally friendly alternative that can help offset heating and cooling costs. With a built-in library of solar and weather data, the module was based on the need for a viable energy-efficient and green alternative to meet user demands and demands dictated by market conditions.
Wrightsoft Corp.
Circle 1

Rooftop air conditioners

Article Tools

Featuring handled access panels, built-in no-strip screws, and integrated terminal boards, the Legacy line of rooftop air conditioners with Puron refrigerant can reach a seasonal energy-efficiency ratio of 13 and an energy-efficiency ratio of up to 11.2. The units include scroll compressors, filter driers, pressure-safety switches, and control boxes.
Bryant Heating & Cooling Systems
Circle 2

Pipe-support systems

Pipe Prop pipe supports elevate and secure all types of pipe and are available with 1½- or 2½-in. saddles to accommodate varying sizes. The units adjust to the necessary height and are affixed to a roof using manufacturer-recommended adhesive.
Pipe Prop
Circle 3

Data-center design/analysis software

6SigmaDC 4 software establishes simulation techniques for the design and operation of data centers through a Virtual Facility (VF). A VF is an exact replica of a space, including angled walls and ventilation ducts. The software enables users to optimize space, power, and cooling.
Future Facilities
Circle 4

Temperature-control valves

Series 38R self-acting temperature-control valves require no external power and are offered in ½- through 6-in. connection sizes and ⅛- through 6-in. port sizes. Valve bodies are available in single-seated direct- or reverse-acting, double-seated direct- or reverse-acting, and three-way designs.
Dwyer Instruments Inc.
Circle 5

Heating/cooling units

For industrial and commercial use, the Workhorse series of heating/cooling equipment includes a direct-fired heater and evaporative cooler in a single unit. FreshWater slinger-wheel technology evenly distributes atomized water across air inlets to ensure efficient cooling.
Bessamaire
Circle 6

Programmable thermostats

The FlexStat BAC-10000 series of intelligent temperature/humidity occupancy-sensing, wall-mounted, thermostats/controllers are native-BACnet advanced application controllers for connection to a BACnet system. The unit simplifies networked zone control for common packaged HVAC equipment, such as packaged rooftop units, fan-coil units, heat pumps, and similar applications.
KMC Controls
Circle 7

Carbon-monoxide detectors

CO1224T carbon-monoxide (CO) detectors include RealTest technology, which can be used to test the detector's CO-sensing cell. In addition, the device has a six-year, end-of-life timer to indicate when detector replacement is necessary.
System Sensor
Circle 8

Send product and literature releases to the attention of Megan White, associate editor, HPAC Engineering, The Penton Media Building, 1300 E. Ninth St., Cleveland, OH 44114-1503; e-mail: megan.white@penton.com. Electronic submissions are preferred.


Acceptable Use Policy
blog comments powered by Disqus

Social Media

Follow us on

Mike Weil Scott Arnold

Marketplace

Recent Comments

Powered by Disqus
Innovative Solutions

Product Reviews of some of the best new HVACR technology...

Best of 2010!

Best of 2010!


Here are HPAC Engineering's top articles of 2010.
Click here to see if your favorites made the list!

Back to Top

Browse Back Issues

January 2012

December 2011

November 2011

October 2011

September 2011

August 2011