Condensing boilers

Sync condensing boilers combine stainless-steel heat-exchanger technology with modulating/condensing combustion to deliver thermal efficiency as high as 98 percent. With models that produce 1.0-, 1.3-, and 1.5-million-Btuh inputs, low-nitrogen-oxide operation, and turndown ratios of 10-to-1, the boilers can serve a range of commercial applications. The boilers' Smart Touch touchscreen control system helps users set up a synchronized green system and allows access to an onboard database of real-time operations data and performance history. Equipped with a built-in cascading sequencer for up to eight boilers, the control system allows the boilers to deliver up to 12 million Btuh of heating capacity. Standard control-system features include outdoor reset, three-pump control, night setback, hot-water generator compatibility, and password security. The boilers feature a space-saving footprint and a direct-vent design with intake and exhaust runs of up to 100 ft. At 58 in. tall and 31 in. wide, the boilers can fit through a standard doorway.
— Lochinvar Corp.
Circle 1

Monitoring kits

Article Tools

HOBO LEED Monitoring Kits enable users to measure and document boiler/solar hot-water performance, rooftop-HVAC-system efficiency, and indoor environmental quality to help improve building performance and earn credits as specified in the Leadership in Energy and Environmental Design for Existing Buildings Green Building Rating System.
— Onset Computer Corp.
Circle 2

Air conditioners

Available in sizes of 2 to 7 tons, Spacemaker Series air conditioners now include a direct-drive fan, environmentally friendly R-410A refrigerant, and energy-saving free cooling.
— Ecosaire
Circle 3

Heaters

Available in five models, wall mounted, gas-fired, forced-draft heaters offer an efficiency of 82 percent. The heaters can be installed in the same spot as many older heaters, using the same gas line and vent hole.
— EuroTherm Systems
Circle 4

Energy-management system

The USE Controller/Energy Management System uses a building's outdoor and indoor temperatures to control a boiler, rather than a traditional heat-timer system that uses only outdoor temperature to trigger a timed heating cycle. On average, the system reduces fuel consumption by 26 percent.
— U.S. Energy Group
Circle 5

Heat pumps

Because of their energy efficiency, Q-Pump heat pumps can help facilities save up to 50 percent on their heating and cooling bills. Able to be incorporated into almost any hydronic loop, the pumps use a four-element refrigeration system that relies on two solenoid valves to redirect refrigerant, eliminating the need for a reversing valve.
— Desert Aire
Circle 6

Low-pressure transducers

CXLdp low-pressure transducers are engineered to provide stable, reliable static- or differential-pressure measurement in HVAC comfort-control systems. A small housing and multiple mounting options allow the transducers to be mounted on a DIN rail, conduit, or wall. With a detachable terminal-block electrical connector, it can be installed on a panel without power interruption.
— Ashcroft Inc.
Circle 7

Industrial fan

The Element is an industrial-grade fan engineered for the needs of large commercial spaces, such as shopping malls, office buildings, churches, and recreational facilities. It features a direct drive that helps move air over large spaces silently and efficiently, requiring minimal energy and maintenance.
— Big Ass Fans
Circle 8

Rooftop air conditioners

Using environmentally friendly Puron refrigerant, WeatherMaker rooftop air conditioners are available in 3- to 10-ton units. The units can reach a seasonal energy-efficiency ratio of 13 and an energy-efficiency ratio of 11.2, making them American Society of Heating, Refrigerating and Air-Conditioning Engineers- compliant and Energy Star-certified.
— Carrier Corp.
Circle 9

Valves

For heating and cooling, iWorX ZV, MV, and FV Series modulating and floating actuation valves can be used in a variety of applications in which accurate control is required, such as hydronic systems, fan-coil units, and reheat on commercial terminal-box units. By accurately controlling flow, the valves reduce sudden changes in supply temperature and provide more even heating and cooling.
— Innovex Technologies
Circle 10

Outdoor-air systems

Dedicated outdoor-air systems can exhaust and supply air from 500 to 2,200 cfm, providing 52°F enhanced dehumidification. High-efficiency direct-drive blower packages are controlled by an independent variable-frequency drive for each air stream. The systems can handle 2 to 10 tons of compressor capacity.
— RenewAire
Circle 11

Equipment flush

Qwik System Flush is a non-toxic, non-flammable, biodegradable refrigeration- and air-conditioning-equipment flush that is effective in removing system-damaging residual oil, moisture, and acid. The flush does not evaporate prematurely, which reduces effectiveness, or contain decafluoropentane and other solutions that can contaminate an environment.
— Mainstream Engineering
Circle 12

Control device

The APR-410 control provides full-capacity modulation for all sizes of direct-expansion air-conditioning systems using R-410A non-ozone-depleting hydrofluorocarbon refrigerant. The control continuously and automatically matches air-conditioning-system capacity/output to changing load conditions. As a result, it provides improved humidity control without overcooling a space.
— Rawal Devices Inc.
Circle 13

Flushometers

Solis Flushometers use light to charge an efficient capacitor, providing power even in rooms with occupancy-controlled lighting. The solar panel powers the unit without the need for moving parts in the waterway, creating better hydraulic performance and reduced maintenance.
— Sloan Valve Co.
Circle 14

Energy-recovery units

Standard features of the VersiVent Model VER energy-recovery unit include a high-performance total energy wheel, a high-efficiency centrifugal plenum supply fan, 2-in. double-wall construction, and hinged access doors. Hot-water, indirect-gas, and electric heating options are available.
— Greenheck
Circle 15

Water heater

The Percomax, a direct-contact, natural-gas-fired water heater, is designed to heat water to temperatures as high as 185°F. Cold water enters the direct-contact water heater at the top and is distributed uniformly over the upper surface of a packing of stainless-steel nodules, which make up the heat-transfer zone.
— Sofame Technologies Inc.
Circle 16

Heat pumps

Well-suited for new school construction and renovation, Quiet Climate 2 wall-mount heat pumps feature two-stage operation and integrated part-load values as high as 15.0 with a variety of ventilation options for better indoor-air quality.
— Bard Manufacturing Co.
Circle 17

Send product and literature releases to the attention of Megan White, associate editor, HPAC Engineering, The Penton Media Building, 1300 E. Ninth St., Cleveland, OH 44114-1503; e-mail: megan.white@penton.com. Electronic submissions are preferred.


Acceptable Use Policy
blog comments powered by Disqus

Social Media

Follow us on

Mike Weil Scott Arnold

Marketplace

Recent Comments

Powered by Disqus
Innovative Solutions

Product Reviews of some of the best new HVACR technology...

Best of 2010!

Best of 2010!


Here are HPAC Engineering's top articles of 2010.
Click here to see if your favorites made the list!

Back to Top

Browse Back Issues

January 2012

December 2011

November 2011

October 2011

September 2011

August 2011