New Products

Energy-recovery ventilators

Energy-recovery ventilators (ERVs) help meet the demand for improved indoor environmental quality (IEQ) by satisfying requirements of ANSI/ASHRAE Standard 62.1, Ventilation for Acceptable Indoor Air Quality, and ANSI/ASHRAE/IESNA Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings. Lossnay ERVs recapture cooling and heating energy, equalize humidity levels, and remove harmful indoor pollutants. They enable users to target different zones with varying heating and cooling needs on a case-by-case basis. The ERVs have a low-maintenance energy-exchange core constructed of a specially treated cellulose-fiber membrane that prevents the mixing of inbound and exhaust air. The ERVs also exhaust irritating indoor pollutants, such as formaldehyde, pollen, cigarette smoke, dust, and carbon dioxide. Air streams are transferred and exhausted through adjacent passages in the core with minimal cross-contamination. During cold months when humidity is low, inbound air is warmed and humidified with warmer indoor air; during warm months, air is cooled and dehumidified with cooler exhausted air, minimizing the load on the cooling and heating system.
Mitsubishi Electric
Circle 1

Dedicated heat-recovery chillers

Article Tools

Able to produce hot water from 110°F to180°F, dedicated heat-recovery chillers recover heat generated during cooling to supplement/replace gas used to heat a building's hot-water boiler. The chillers are useful in buildings that need cold air for computer rooms, laboratories, and storage areas while requiring heat for hot water, processing, and sterilization.
Multistack
Circle 2

Rooftop units

Precedent 3- to 10-ton light-commercial rooftop units cool and condition air while surpassing the energy-efficiency-ratio minimum by 12 percent. The units offer easy access to filters and controls through single side-access doors.
Trane
Circle 3

Air conditioners

For critical environments such as data-equipment centers and medical-equipment rooms, the Ecosaire EN Series of 7½- to 30-ton air conditioners offers a 95- to 98-percent sensible-heat ratio. The air conditioners use environmentally friendly R-410A or R-407c refrigerant.
Dectron Inc.
Circle 4

Gasketed plate heat exchangers

TL15-B gasketed plate heat exchangers are designed for applications that have a high demand for thermal heating and cooling efficiency and require a close temperature approach and large temperature change, such as pressure breakers, district-cooling interchangers, and heat recovery.
Alfa Laval
Circle 5

Gas-fired heaters

With models ranging from 135,000 to 310,000 Btuh, Effinity93 gas-fired unit heaters feature a Conservicore high-grade stainless-steel secondary heat exchanger designed to withstand the acidic condensate that is a byproduct of the combustion process.
Modine Manufacturing Co.
Circle 6

Water-source heat pumps

Offering multiple cabinet configurations and available in 7- to 25-ton units, Tranquility Large Vertical (TLV) heat pumps use EarthPure HFC-410A refrigerant. The units are designed to be field-convertible to front or back return and top, front, or back discharge. Compressor mounting and belt-drive blowers help minimize vibration/sound attenuation.
ClimateMaster
Circle 7

Circulators

Available in cast-iron or stainless-steel, SuperBruteXL three-speed wet-rotor circulators have a flow range of 0 to 65 gpm and a head range of 0 to 46 ft. The units can handle fluid temperatures from 36°F to 195°F with a maximum working pressure of 145 psi.
Grundfos
Circle 8

Send product and literature releases to the attention of Megan White, associate editor, HPAC Engineering, The Penton Media Building, 1300 E. Ninth St., Cleveland, OH 44114-1503; e-mail: megan.white@penton.com. Electronic submissions are preferred.


Acceptable Use Policy
blog comments powered by Disqus

Social Media

Follow us on

Mike Weil Scott Arnold

Marketplace

Recent Comments

Powered by Disqus
Innovative Solutions

Product Reviews of some of the best new HVACR technology...

Best of 2010!

Best of 2010!


Here are HPAC Engineering's top articles of 2010.
Click here to see if your favorites made the list!

Back to Top

Browse Back Issues

January 2012

December 2011

November 2011

October 2011

September 2011

August 2011