Market Leaders
Page 3 of 3
Ventilation-system controls
For commercial-kitchen ventilation systems, Intelli-Hood controls can save up to 50 percent of energy. Featuring optic and temperature sensors, the controls can be retrofitted to any hood. Visit www.melinkcorp.com for more information.
— Melink Corp.
Circle 13
BIM 3D CAD drawings
Building-information-modeling 3D computer-aided-design drawings for engineered piping products can be downloaded at no cost at www.metraflex.com/bim. The drawings are available for expansion joints, connectors, strainers, pipe guides, compensators, valves, etc. Various file formats are available for users' specific design software.
— The Metraflex Co.
Circle 14
Control valve
Available in ½- to 2-in. sizes, the AB-QM Pressure Independent Control Valve (PICV) combines automatic flow and temperature control into one device. The valve is available with several different actuators, including three-wire floating, 0- to 10-v proportional, and self-contained thermal actuation. For more information, Visit www.nexusvalve.com.
— Nexus Valve
Circle 15
Flow meters
F-2500 Series Vortex Mass Flow Meters provide accurate, direct mass-flow measurement of steam, compressed air, and gases without the need for an external flow computer. Continuous real-time density calculations are performed internally using integral flow, temperature, and pressure-sensor data. A two-stage bluff body/sensor design enhances signal sensitivity and extends meter operating range.
— Onicon Inc.
Circle 16
Boiler
Listed by a North American testing laboratory as a complete gas-fired boiler/burner assembly in the United States and Canada, the G3120R Water Wall boiler has an input of 3,120,000 Btu. It has been tested with results of more than 86-percent efficiency. Visit www.parkerboiler.com for more information.
— Parker Boiler
Circle 17
Ventilation products
RenewAire's static-plate core is used in energy-recovery-ventilation systems ranging from small commercial to dedicated outdoor air. RenewAire products improve indoor-air quality by providing exhaust and fresh-air supply simultaneously and reducing the concentration of harmful pollutants while transferring heat and humidity without mixing air streams. For more information, Visit www.renewaire.com/for_commercial_buildings.
— RenewAire LLC
Circle 18
Air-measurement dampers
EAMS060 electronic air-measurement dampers are BACnet-compatible and utilize a single mass-flow sensor to achieve Air Movement and Control Association International Inc.- (AMCA-) certified ratings of ±3 percent down to 50 fpm. The dampers save energy with AMCA Class 1 leakage and meet International Energy Conservation Code requirements. Electronic controls are temperature and altitude compensating. For more information, Visit www.ruskin.com.
— Ruskin
Circle 19
Variable-speed drives
Altivar 12 variable-speed alternating-current drives deliver flexibility, performance, and energy efficiency in a compact design. The drives feature starting and stopping motor performance that eliminates the need to oversize a drive or add dynamic braking in most HVAC applications. The drives also can rapidly detect motor-current peaks.
— Schneider Electric
Circle 20
Solar control circulator
For the clean-energy solar-thermal market, the Variable Speed Solar Control Circulator continuously optimizes water flow through a solar collector to achieve maximum energy gain. The circulator maximizes energy gain by maintaining the proper delta-T through a solar collector over an extended period of time. The circulator continuously adjusts its speed, maximizing the output of a collector while increasing usable higher-temperature water throughout the day, eliminating short cycling and increasing performance by 20 percent. For more information, Visit www.taco-hvac.com.
— Taco Inc.
Circle 21
High-intensity heaters
Sun-Twin two-stage high-intensity heaters provide energy savings of up to 75 percent and extreme-cold-weather protection. For areas near doors where quick heat-recovery times are needed, the heaters operate on natural or propane gas. For more information, Visit www.solaronicsusa.com.
— Solaronics Inc.
Circle 22
Spot air conditioners
MovinCool offers a range of portable and ceiling-mounted spot air conditioners. Useful for data centers, offices, hospitals, schools, warehouses, and manufacturing plants, the units are used for emergency-backup, supplemental, and permanent cooling. Portable models can be wheeled into place quickly when needed with almost no installation. The company's latest compact, ceiling-mounted unit allows easy installation in tight spaces.
— MovinCool
Circle 23
Want to use this article? Click here for options!
© 2012 Penton Media Inc.
Acceptable Use Policy blog comments powered by Disqus








Recent Comments