Heating circulator
Bell & Gossett’s energy-efficient SMART heating circulator uses a unique technology to achieve significant energy savings while delivering hot water throughout a commercial or residential property. Featuring electronically-commutated-motor technology and a patented spherical motor design, ecocirc pumps eliminate the need for a conventional shaft, seal, and bearing assembly. Other special features of the pumps include control modes (auto for automatic proportional pressure control and vario for stepless speed control with a constant curve) and maintenance-free, long-lasting operation. The pumps are seal-less and leak-free, as well as self-lubricating and automatically cooled by pump media. Energy savings pay back the cost of the pumps within months.
Bell & Gossett
8200 N. Austin Ave.
Morton Grove, IL 60053
847-966-3700
www.completewatersystems.com
Insulated saddles and clevis-hanger covers
New CoolDry insulated saddles and matching Wraparoos clevis-hanger covers provide water- and moisture-resistant insulation and jacketing. The chlorofluorocarbon- and hydrochlorofluorocarbon-free phenolic-foam insulation has excellent compressive strength (3.75 PCF and 5 PCF) and meets rigid 25/50 flame/smoke ratings, while the vapor-barrier jacketing with self-sealing tape is zero-permeance-rated. A unique partial-bottom ribbed saddle secures the CoolDry system, while the bright-white polyvinyl-chloride Wraparoos clevis-hanger cover protects the saddle and cleans easily with a damp cloth.
Buckaroos Inc.
9635 Park Davis Drive
Indianapolis, IN 46235
800-969-3113
http://http://buckaroos.com
Differential-pressure switch
The Series 1831 differential-pressure switch with manual reset eliminates common problems associated with typical high-duct-static-cutout installations. With no power required to drive its outputs, a separate power loop and associated wiring and conduit is avoided. Both control contacts activate at the same time. The potential of the lead switch shutting down the fan, preventing the lag switch from sending an alarming signal to the DDC, no longer is a probable system liability. Potential costly maintenance calls are diminished. For more information, go to http://bit.ly/Series_1831.
Dwyer Instruments Inc.
P.O. Box 373
Michigan City, IN 46361
219-879-8000
www.dwyer-inst.com
Plug fans
Centrifugal series plug fans with GreenTech EC technology have been improved. All fans above a 500-w drive output can be controlled by Modbus and 0 to 10 v. Gaps that existed in the product range were filled, as the series has been expanded with larger diameters. Plug fans are equipped with a stable base frame that enables the entire unit to be decoupled from vibrations in the environment, making it possible to serve additional applications, not just heating and ventilation. Twelve sizes are available, with outer diameters ranging from 250 to 900 mm. For more information, go to http://info.ebmpapst.us/plugfans.
ebm-papst Inc.
100 Hyde Road
Farmington, CT 06034
860-674-1515
www.ebmpapst.us
Airflow-measurement damper
Ebtron Inc. and TAMCO completed joint engineering, testing, and production-system integration for the AIR-IQ airflow-measuring-damper assembly. Comprehensive testing verified reliable unducted accuracy of ±5 percent of reading throughout the entire measurement range and up to Class 1A damper-leakage performance for compliance with ANSI/ASHRAE/IESNA Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings. A wide range of damper models and options provide designers with thermal-break frame design, thermally insulated airfoil blades, a salt-water-corrosion-resistance option, and dual-bearing and slip-proof-linkage designs for maintenance-free operation and 20-plus-year service life. For more information, visit http://ebtron.com/ or http://tamcodampers.com/.
Ebtron Inc.
1663 Highway 701 S.
Loris, SC 29569
800-232-8766
http://ebtron.com/
Heat pumps
The RedLINK wireless HVAC protocol in Mitsubishi Electric Cooling & Heating split-ductless and ducted heat pumps allows users to maximize comfort and reduce energy costs. Using radio-frequency communication, a single controller can manage up to 16 zones and be placed in a different room than an air handler. To learn more, visit http://bit.ly/MitsubishiElectric_RedLINK.
Mitsubishi Electric Cooling & Heating
3400 Lawrenceville Suwanee Road
Suwanee, GA 30024
800-433-4822
www.mitsubishipro.com
Free-cooling chillers
Motivair air-cooled free-cooling chillers are designed for year-round cooling loads and mission-critical applications from 7.5 to 350 tons. All models feature a complete refrigeration plant with R-407C scroll compressors to 75 tons or dual R-134A screws to 350 tons. Standard features include integrated free-cooling coils and three-way valve. Optional features include circulation pumps, storage tank, and building-management-system interface. Software provides rapid restart after power failure and maximum free-cooling operation in low ambient temperatures. Free-cooling chillers dramatically reduce data-center power costs when applied with the Motivair Chilled Door high-density rack-cooling system.
Motivair Corp.
85 Woodridge Drive
Amherst, NY 14228
716-691-9222
www.motivaircorp.com
Flow meter
ONICON’s F-3500 insertion electromagnetic flow meter is engineered to excel in demanding water-flow-measurement applications. With no moving parts, the F-3500 is reliable even in challenging open-loop applications. The hand-insertable hot-tap design provides quick, easy installation. Every meter is individually wet-calibrated to NIST traceable standards, programmed for your application, and accurate to within 1 percent of rate.
ONICON Inc.
1500 N. Belcher Road
Clearwater, FL 33765
727-447-6140
www.onicon.com
Corrosion-under-insulation solution
Polyguard’s ReactiveGel products are a solution to most problems of corrosion under insulation. ReactiveGel prevents corrosion on steel pipe, while Polyguard’s tough Zeroperm vapor barriers prevent wet insulation and mold formation. Contact Nate Brink at 312-218-3560 for engineering information.
Polyguard Products
3801 S. Interstate 45
Ennis, TX 75119
214-515-5000
http://www.reactivegel.com/
Programmable logic controller
The new Modicon M168 programmable logic controller by Schneider Electric helps HVACR OEM customers improve their machine performance and speed up time to market with flexible architecture and customized design. The Modicon M168, combined with the complete line of Schneider Electric components and variable-frequency drives, helps OEMs deliver an innovative and single-source solution. To learn more, go to http://bit.ly/Modicon.
Schneider Electric
1415 S. Roselle Road
Palatine, IL 60067-7399
847-397-2600
www.us.schneider-electric.com
Mixing block
Taco’s LOFlo Mixing Block works with the company’s LoadMatch single-pipe system, along with active/passive chilled beams and a 100-percent dedicated outside-air system, to supply latent cooling. Together, these elements form the Taco LOFlo Mixing Block System, providing an injection-pumping system that is energy-efficient, lowers first costs, eliminates balancing problems, simplifies commissioning, reduces callbacks, and maximizes occupant comfort throughout a building.
Taco Inc.
1160 Cranston St.
Cranston, RI 02920
401-942-8000
www.taco-hvac.com
Thermal-imaging camera
The new Wahl Heat Spy thermal-imaging camera is the world’s first upgradable thermal imager. The z30 Series Detector is designed for on-the-spot maintenance inspections and repair. The z50 Series Inspector allows users to document and prepare reports with ease, providing thermal and digital images. Upgrade in the field from a Detector to an Inspector after your purchase to expand the functionality of your camera. Prolong the life of your investment by extending the temperature range or adding wide-angle and/or telescopic lenses. To learn more, visit www.wahlheatspy.com, or write to sales@palmerwahl.com.
Wahl Instruments Inc.
234 Old Weaverville Road
Asheville, NC 28804
800-421-2853
www.palmerwahl.com
AC drive
The Yaskawa Z1000 AC drive is designed for such building-automation applications as fans, pumps, and cooling towers through 500 hp. It features an easy-to-read LCD keypad that provides hand/off/auto interface and a real-time clock. It protects against drive and motor faults to maintain uptime and conforms to the BACnet communication protocol standard. Yaskawa America Inc.—Drives & Motion Division
2121 Norman Drive S.
Waukegan, IL 60085
800-927-5292
http://bit.ly/Yaskawa-America









