2009 AHR EXPO Product Review

Condensing economizers

e++plus condensing economizers provide peak efficiencies of up to 90 percent, depending on flow rates and the temperature of the incoming water being heated. The lower section of the economizer recovers heat energy by preheating boiler feed water. The upper section preheats cool liquid steam. The control system ensures maximum condensing when firing natural gas and automatically switches to a near-condensing mode if No. 2 oil is to be burned.
Cleaver-Brooks
Circle 1

Multistory fireplace and exhaust system

Article Tools

Exhausto offers a certified combination fireplace and mechanical exhaust system for multiple-fireplace installations in multistory structures. The system saves energy through a modulating draft that provides fireplace efficiency and performance. Designed for natural- and liquefied-petroleum-gas fireplaces, the system is controlled with simple on and off buttons.
Exhausto
Circle 2

Combustion air blowers

For gas-fired condensing boilers, NRG137 combustion air blowers feature a compact design, an aerodynamic impeller, and an optional integrated venturi for high heating capabilities and inputs of up to 150 kw (512,000 Btuh). Microprocessor-controlled drive electronics improve power output and reduce motor noise by 3 dba. The blowers are available in 120 or 230 vac and 50/60 hz.
ebm-papst Inc.
Circle 3

Chemical filter media

GridBlok chemical filter media, housed within PuraGrid filters, consist of an extruded monolithic block containing a large number of small, parallel cells/channels. Each piece of the media is a self-supporting grid structure composed of 100-percent adsorbent materials, allowing the composite structure to serve as a gas filter. Eliminating bypass and the necessity of a final filter, the media provide energy savings with a low pressure drop and efficient gas removal with turbulent flow.
Purafil Inc.
Circle 4

Heat pumps

Six Energy Star mini-split heat pumps from Fujitsu need no modifications for low-ambient operation. A 9,000-Btu model provides a seasonal energy-efficiency ratio (SEER) of 26 and a heating-season performance factor (HSPF) of 12. A 12,000-Btu model offers a SEER of 25 and an HSPF of 12. Two other 9,000- and 12,000-Btu models have SEERs of 20 and HSPFs of 10. Standard features include wireless remote control, ion deodorizing filters, a sleep timer, a 24-hr timer, and dry, auto-louver, and auto modes.
Fujitsu
Circle 5

Communications module

Used in the Allen Bradley ControlLogix programmable logic controller (PLC), the SlotServer communications module gives process-control facilities the ability to link building-automation, fire-alarm-panel, and process-control networks. Process plants utilize ControlLogix PLCs to control operations and building-automation information necessary for the efficient performance of the plant and process.
FieldServer Technologies
Circle 6

Control software

OptimumHVAC software allows building engineers to analyze HVAC-system performance and troubleshoot in real time over the Internet. By tracking building performance remotely, the software measures and verifies equipment operation and savings on a real-time and historical basis. The software's delivery options consist of OptimumLOOP, which targets buildings over 300,000 sq ft that have centrifugal chiller plants, and OptimumTRAV, which is designed for buildings with variable-air-volume air-handling units.
Optimum Energy LLC
Circle 7

Infrared cameras

In addition to 2-percent thermal accuracy, Flir i60 infrared cameras offer scalable picture-in-picture, a 32,400-pixel infrared detector, 2.3-megapixel visual resolution, built-in illuminator lamps, sharable JPEG images, and a 5-hr battery.
Extech Instruments
Circle 8

Heat packs

Add-on modules that fit onto the core of Phoenix water heaters, Phoenix Heat Packs are available in domestic-hot-water and space-heating models. The modules consist of a heat exchanger and pump to move water through the water-heater system. Warm water is drawn from the top of the storage tank, through the brazed-plate heat exchanger, and returned to the bottom of the tank for reheating. The modules are pre-plumbed and wired for ease of installation.
Heat Transfer
Circle 9

Head-pressure control

Practical for supermarkets, frozen-food storage, computer rooms, and cooling-tower fans, the ICM333 head-pressure control operates as a pressure or temperature-sensitive motor-fan speed control, regulating head pressure by varying the amount of airflow through the condenser. By allowing for dual probes, the control is useful for a range of systems, including single-fan, multicoil systems.
ICM Controls Corp.
Circle 10


Acceptable Use Policy
blog comments powered by Disqus

Social Media

Follow us on

Mike Weil Scott Arnold

Marketplace

Recent Comments

Powered by Disqus
Innovative Solutions

Product Reviews of some of the best new HVACR technology...

Best of 2010!

Best of 2010!


Here are HPAC Engineering's top articles of 2010.
Click here to see if your favorites made the list!

Back to Top

Browse Back Issues

January 2012

December 2011

November 2011

October 2011

September 2011

August 2011