2009 AHR Expo Product Preview

Coil cleaners

Article Tools

Practical for smaller rooftop units, hard-to-reach air handlers, and refrigeration condenser coils, CoilPro Jr. coil cleaners include a 125-psi pump, a deep-cycle battery, operator-controlled chemical injection, and custom accessories.
— Goodway Technologies Corp.

Commercial comfort systems

Light-commercial Series 10 comfort systems have a 6½- to 12½-ton cooling- and 90- to 190-mbh heating-range capacity. Each system features two compressors, independent refrigeration circuits, and foil-faced insulation. The systems are available in cooling-only, cooling-with-electric-heat, and cooling-with-gas-heat configurations.
— Johnson Controls

Heating manifolds

Made of thermoplastic high-performance materials, engineered-plastic heating manifolds for radiant applications resist corrosion, pitting, scaling, elevated chlorine levels, and ultraviolet light and are suitable for use under of high impact, heat, and moisture conditions. The manifolds are available in two to eight loops and accommodate 15.4 gpm. The manifolds offer vent and purge capabilities, and attached flow meters provide balancing for radiant loops.
— Uponor Corp.

Duct smoke detectors

InnovairFlex duct smoke detectors offer false-alarm immunity, a broad temperature range from -4 to 158°F, visible status indicators, and an accessible test feature. One unit can accommodate multiple installation footprints to overcome mounting constraints.
— System Sensor

Water filters

Automatic self-cleaning water filters remove micron-size suspended solids, independent of specific gravity, from water in once-through and recirculating systems, such as cooling, process, reclaim, effluent, intake, and wash waters. Single filters handle flow rates up to 12,000 gpm but can be banked to handle unlimited flows. Water-filter installation can be vertical, horizontal, or diagonal in new or existing piping systems.
— Orival Water Filters

Chillers

Air-cooled chillers are available from 7½ to 350 tons with integrated free cooling. Fifty-percent free cooling is achieved with ambient temperatures 10°F below chilled-water temperature and 100-percent free cooling with 20°F differential. The chillers offer energy savings for any year-round cooling application, such as data centers and other mission-critical sites. Typical investment payback occurs in less than one year.
— Motivair

Energy-savings software

Energy-savings-predictor software includes a customizable carbon-footprint/emissions-calculation module that shows the immediate carbon-dioxide savings of a Yaskawa drive vs. a conventional flow-control method. The software is optimized for Windows XP and Vista and includes a project-management module that allows users to create projects containing multiple systems of different sizes, such as fan, pump, and cooling-tower-fan systems.
Yaskawa

Trim systems

Temp-A-Trim air-density trim systems offer fuel savings up to 3 percent by maintaining optimal burner-combustion efficiency. The systems sense combustion air temperature and automatically vary burner fan speed to create a constant mass airflow, thereby maintaining optimal combustion efficiency. No special setup is required.
— Webster Engineering

Dampers

HBTR-451 dampers are recommended for two-position shut-off applications including medical facilities, laboratories, food processing, military facilities, campuses, clean rooms, and microelectronic manufacturing. The dampers feature a silicone blade seal and are double-gland axle-seal factory-leakage tested to ensure bubble-tight performance up to 30-in.-wg differential pressure.
— Greenheck

Drain sensors

Designed for use with Blue Diamond condensate pumps, DrainStik sensors automatically start and stop the pumps when condensate is present. A slim-line probe, which houses water sensors and a high-level alarm, can be mounted directly into the drain tube of all types of equipment. With no moving parts, the sensors are an alternative to existing float switches.
— Charles Austin Pumps


Acceptable Use Policy
blog comments powered by Disqus

Follow us on

Mike Weil Scott Arnold

HPAC Engineering eNewsletters

Marketplace

Recent Comments

Powered by Disqus
Innovative Solutions

Product Reviews of some of the best new HVACR technology...

Best of 2011!


Here are HPAC Engineering's top articles of 2011.
Click here to see if your favorites made the list!

Back to Top

Browse Back Issues

May 20121

April 2012

March 2012

February 2012

January 2012

December 2011