2012 AHR Expo Product Preview
Cooling-tower fan
The Whisper Quiet Fan for Baltimore Air Coil’s PT2 cooling tower provides 12- to 15-dBA sound reduction, has Cooling Technology Institute-certified thermal capacity, and is compliant with ANSI/ASHRAE/IESNA Standard 90.1. The chemical-resistant, durable, high-solidity, single-piece, molded fan made out of fiberglass reinforced polyester. It is fully factory-installed and aligned, and requires no field installation.
—Baltimore Aircoil Company
Insulation encapsulant
RE-500 is a high-performance, antimicrobial, robotically applied insulation encapsulant. The low-volatile-organic-compound coating is ideal for projects such as hospitals and schools, where disruption of the building’s occupants cannot be tolerated. Its semigloss finish provides a surface that prevents debris accumulation that could lead to mold growth.
—Carlisle HVAC
Pump-system-configuration software
PUMP-FLO Insight configuration software is designed to automate the quote-to-production process. The scalable, Web-based, and secure cloud-computing technology allows integration with computer-aided-design, enterprise-resource-planning, and other systems, as well as with PUMP-FLO electronic catalogs.Additional functionality includes quote and proposal generation; bill-of-materials, pricing, costing, and discounting modules; and the ability to generate manufacturing routing reports.
—Engineered Software Inc.
Capacitance transmitter
The CS01 RF capacitance transmitter offers a compact and affordable option for a wide variety of level-sensing applications. With 4–20 MA and 0–5 VDC selectable outputs, the solid-state sensor provides accurate, proportional level measurement in many extreme process temperatures and fluid conditions. It features a simple, fully programmable, four-button calibration to set for whatever media it is measuring.
—Innovative Solutions
Variable-refrigerant-flow system
The Multi V III variable-refrigerant-flow (VRF) commercial air-conditioning system for large-scale facilities such as commercial office buildings, hotels, hospitals, and schools offers Air-Conditioning, Heating, and Refrigeration Institute-certified ratings, fast-response cooling, and a space-saving footprint. The VRF technology improves energy efficiency by allowing occupants to choose whether to air-condition or heat only the zones in use. The units feature an inverter scroll that offers a more compact size for the same capacity output with greater reliability in cold climates compared with previous Multi V systems.
—LG Electronics
Fluid-sensing and power supplies
A full line of fluid-sensing and power products from Standex Electronics includes inductors, current sensors, and power transformers. These components allow system designers to incorporate upstream and downstream components to streamline production and assembly, saving labor and component costs. The products are manufactured in ISO-registered facilities close to the worldwide usage point, thus simplifying logistics and reducing shipping costs. Standex also offers in-house molding, rapid prototyping, and the ability to wind and assemble all core transformer types.
—Standex Electronics
BAS and embedded technology products
NiagaraAX Release 3.6 is one of several building-automation, energy-management, and embedded-technology-for-device-to enterprise-integration products being presented at the AHR Expo. NiagaraAX Release 3.6, the latest release of the NiagaraAX Framework, includes many recently added features and enhancements, including support for batteryless options and 802.11 WiFi, heightened security features, and a number of usability enhancements. Also being displayed are the Metering Gateway, Sedona Framework TXS 1.1, and Niagara Security 2.2.
—Tridium
Drive for fans and pumps
The Z1000 variable-speed drive is designed for building-automation applications such as fans, pumps, and cooling towers through 500 hp. It features an easy-to-read LCD keypad that provides hand/off/auto interface and a real-time clock.
—Yaskawa
Fiber-free duct liner
AP Coilflex duct liner is fiber-free and manufactured without chlorofluorocarbons, hydrofluorocarbons or hydrochlorofluorocarbons. It is designed for air-handling systems, variable-air-volume units, ducts, and other air-system components that require condensation control and resistance to moisture, damage, or heat gain. It reduces noise generated by fans and air movement.
—Armacell
Wide duct wrap
WideWrap is a fiberglass duct-wrap product with 5 ft width designed to work perfectly with 5-ft duct sections and eliminate the need for additional fabrications. The foil scrim kraft (FSK)-faced flexible fiberglass blanket insulation is used to insulate the exterior of rectangular and round ductwork to provide enhanced thermal efficiency and reduce unwanted heat loss or gain.
—CertainTeed
Large-diameter fans
Low-speed fans in 6-ft to 24-ft diameters generate year-round, energy-efficient air circulation. The Isis fan is designed and engineered to dramatically improve air circulation in large areas, including industrial, agricultural, and commercial spaces.
—Big Ass Fans
Customizable IAQ monitor
The IAQPoint2 is a touchscreen, customizable, indoor-air-quality monitor that can control carbon dioxide, volatile organic compounds, temperature, and humidity. The unit boosts energy efficiency, fresh-air comfort, and the alertness and performance of building occupants through on-demand ventilation activation, with relays triggering fans via multianalog options or a building automation system.
—Honeywell Analytics
VFD shaft-voltage test kit
The AEGIS Shaft Voltage Test Kit is designed to make measuring and documenting variable-frequency-drive- (VFD-) induced voltages easy. Motors controlled by VFDs are vulnerable to electrical bearing damage. Although specifiers may choose motors that are equipped with shaft-grounding rings, the shaft-voltage test kit may be used in retrofit applications while there is still time to head off damage and downtime. The kit includes a specially tipped probe and a portable oscilloscope.
—Electro Static Technology
Centrifugal fans
RadiCal centrifugal fans feature impellers of size 133 to 250 that are manufactured in one piece, allowing them to attain a high rotational speed. The styling of the impeller has been optimized to provide low-loss flow of air through the impeller without drastic cross-sectional changes.
—ebm-papst
Variable heat pump with auxiliary gas heat
The Rebel packaged rooftop system combines variable-heat-pump technology with auxiliary gas heat and a variable-inverter scroll compressor, while functioning as a variable-air-volume heat-pump unit down to 3 tons. The electronically commutated motors used on the fans allow for variable-speed operation. The units are available in 3- to 15-ton sizes, offer a modulating hot-gas-reheat option, and operate efficiently in colder weather. As a dedicated-outdoor-air system, the units provide energy-efficient makeup air for 100 percent outdoor-air applications.
—Daikin McQuay